top of page

Reliability-Constrained Capacity Planning for School Organic-Waste Networks Under Uncertainty

Christopher Dylan Suruadji
09/11/2026

School organic-waste networks face uncertain collection and treatment disruptions. This study compares 231 capacity configurations in a hypothetical eight-school network using 50,000 simulated training weeks and an independent 100,000-week Monte Carlo evaluation. Binomial screening limits failure probability, while tail and conditional-loss measures distinguish infrequent shortfalls from severe failed weeks.
The baseline-selected hybrid places 20% of rated capacity at a shared facility and installs 25% reserve. Its held-out failure frequency is 2.35%, and it wins all 20 independent training replications. At equal capacity, this split minimizes CVaR₀.₉₅ at 25% reserve, but conditional mean shortfall increases with the shared fraction. The original 100-kg CVaR₀.₉₅ screen permits large losses during failures; adding a conditional-mean limit selects a different hybrid, and combining it with a worst-1% limit increases reserve.
The baseline hybrid exceeds its original severity limit in three of five stress tests. Its small economic advantage and sensitivity to service criteria and facility charges do not justify prescribing an exact split generally. The contribution is a reproducible comparison of reserve placement, failure severity, and school-level service; operational use requires measured loads, technology-specific availability, costs, and backup capacity.