Comparative Evaluation of PCM, Air Cooling, and Hybrid PCM-Air Cooling for Thermal Management of a Dry 18650 Cell

Armaan Mittal
21/11/26

Thermal management is crucial to the safe, reliable performance of lithium-ion batteries. The thermal performance of a dry 18650 cell is experimentally compared in four states: no cooling, phase change material (PCM) cooling, fan cooling and hybrid PCM + fan cooling. The temperature of the cells was recorded during the 20 min experimental period, and the thermal responses of the four configurations were compared. The no-cooling condition achieved a temperature of 28.40 °C at 20 min, while the PCM, fan and hybrid PCM + fan cooling conditions had temperatures of 27.48, 26.10 and 25.38 °C, respectively. The corresponding final-temperature differences from the no-cooling condition were 0.92, 2.30, and 3.02 °C. Under the experimental conditions tested, the PCM + fan configuration produced the lowest recorded battery temperature compared with PCM cooling, fan cooling, and no cooling. Recorded cell temperatures remained below 30 °C, below the approximately 43 °C PCM melting point; latent-heat storage was not demonstrated. Unequal first-recorded temperatures and current profiles, together with undocumented ambient temperatures and replication, limit causal attribution to cooling alone. The robustness and applicability of the hybrid system should be further investigated under various discharge rates, ambient temperatures, airflow conditions and longer operating durations.