top of page

Conceptual Design of a Dual-Function Bus Handle Rail System for Wheelchair Boarding and Interior Support: A Preliminary Scoping and Analysis Study

Dongyun Hwang
29/10/2026

Low-floor buses improve physical access to public transportation, but wheelchair users may still encounter gaps in reachable support while boarding, moving through the bus interior, and positioning within the designated wheelchair space. This study presents the conceptual design of a dual-function ceiling-mounted rail intended to serve as a conventional handrail for non-disabled passengers and as a supplementary guidance and support element for wheelchair users during boarding, circulation, and positioning.

A structured field audit was conducted on a convenience sample of 18 low-floor buses across nine Seoul routes. No dedicated wheelchair-user support handle was observed in the sampled vehicles, and the nearest fixed graspable support adjacent to the wheelchair space was a vertical pole in all 18 buses. The horizontal distance to this support ranged from 49 to 71 cm, with a mean of 61.9 cm, while the maximum unsupported gap along the boarding-to-wheelchair-space path ranged from 200 to 223 cm, with a mean of 214.7 cm. These measurements informed the requirement for more continuous and reachable interior support.

Simplified engineering analyses were then used to test specific features of the proposed concept against external criteria. Under an assumed pivot torque of 12 N·m, lever lengths from 0.10 to 0.30 m required 40 to 120 N of operating force, all exceeding the 22.2 N accessibility reference for operable parts. Estimated contact forces ranged from about 1.5 to 60 N across the sensitivity range and were compared with ISO/TS 15066 body-region limits as non-transit-specific screening references. Published city-bus hard-braking data reaching 0.75 g correspond to an estimated inertial load of approximately 660 N for the assumed 90 kg wheelchair-and-occupant mass, which is used only as a structural reference for the rail mounting. Four preliminary design requirements were derived, covering continuous support along the boarding path, mounting strength, controlled handle movement, and reachable low-force operation.

The proposed rail should therefore be understood as a preliminary boarding, circulation, and positioning aid rather than an occupant-restraint system. Prototype testing, user evaluation, and validation of the mechanism, actuation method, structural mounting, and safety features are required before accessibility improvements can be established.

bottom of page